Parameter
|
Value
|
Output Interface
|
Waveguide, WR-75
|
Output Power @ P1 dB
|
+37 dBm minimum over temperature
|
Conversion Gain
|
53 dB Min.,60 dB nominal
|
Required Frequency
External Reference
Input Power
Phase Noise
|
10 MHz (sine-wave)
-5 to +5 dBm @ Input port
-30 dBc/Hz max. @ 10Hz
-60 dBc/Hz max. @ 100 Hz
-70 dBc/Hz max. @ 1 kHz
|
|
-80 dBc/Hz max. @ 10 kHz
-90 dBc/Hz max. @ 100 kHz
-100 dBc/Hz max. @ 1 MHz
|
Input V.S.W.R.
|
2:1 max
|
Output V.S.W.R.
|
2:1 max
|
|
|
Parameter
|
Value
|
DC Power Requirement
|
+15
to +24 V
|
Mute
|
Shut off the HPA in case of LO unlocked
|
Input Interface
|
N-type, female (50 Ohm)
F-type, female (75 Ohm)
|
Power Consumption
|
39 W max.
|
Operating Temperature
|
-40 to +55 degrees C
|
Storage Temperature
|
-40 to +75 degrees C
|
Size(mm)
|
172.4 (L) x 171 (W) x 58 (H)
|
Weight(kg)
|
1.9 (max.)
|
|